NEW QUESTION 121
In the FusionModule1000, all the fire-fighting cables of the open line are worn with metal hoses, and the pipe ends are protected by a wire sleeve to prevent damage to the fire-fighting cables when a fire occurs.
- A. True
- B. False
Answer: A
NEW QUESTION 122
Every time NetCol5000-C startup, settings values need to be reset.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 123
To modify the micro-module view of ECC800,users need to log in the WebUI as as admin.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 124
On the NetEco WebUI, one modular can be bound to a maximum of ( ) ECC800(s).
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION 125
After the NetCol5000-A25kW half-cabinet air-conditioning refrigerant pipeline is installed, do the nitrogen charge pressure maintaining, the nitrogen pressure is () Mpa.
- A. 0
- B. 1
- C. 2.5
- D. 0.8
Answer: B
NEW QUESTION 126
The UPS5000-S-400K uses a ( ) kVA power module.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION 127
When a backfeed occurs in main or bypass, the backfeed protection card can send signals to trip the input circuit breaker.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 128
By setting the mailbox parameters, the NetEco system will send an email to notify the user according to the set rules.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 129
Which are optional parts of NetCol8000-C?
- A. Humidifier
- B. Differential pressure sensor
- C. Air filter
- D. Electric heater
Answer: A,B,D
NEW QUESTION 130
Huawei NetCol5000-A line-level precision air conditioner mainly solves the hot issue of high-density data center
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 131
Which components can be installed onto the guide rail?
- A. AC Actuator
- B. Access actuator
- C. ETH converter
- D. Skylight Actuator
Answer: A,D
NEW QUESTION 132
In the FusionModule1000, all surface-mounted fire control cables are rounded through metal hoses to prevent damage in case of fire.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 133
On the NetEco, the door name can't be modified.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 134
When four UPS2000-G-20K parallel setting is "3+1", the capacity of the system is ( ) KVA.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION 135
The refrigerant air cylinder of the Huawei air-cooled air conditioner does not need to be inverted on the electronic scale when charging the refrigerant.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 136
The compressor discharge temperature of NetCol5000-A is high, the possible reasons ( ).
- A. The refrigerant loop or component is blocked.
- B. The condenser is dirty or blocked.
- C. The refrigerant is insufficient
- D. The outdoor unit is not properly installed.
Answer: A,B,D
NEW QUESTION 137
When installing the UPS battery, the installation tool does not need to be insulated because the load is not charged.
- A. False
- B. True
Answer: A
NEW QUESTION 138
In NetCol5000-A compressor, if many bubbles exist in the oil sight glass, it indicates that the superheat degree is high.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 139
If UPS5000-E works in maintenance bypass mode, bypass module cannot work.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 140
The humidifier that used in NetCol8000-A is ().
- A. High-pressure micro-mist humidifier
- B. Wet film humidifier
- C. Electrode humidifier
- D. Infrared humidifier
Answer: D
NEW QUESTION 141
ECC800 does not support alarm notification in SMS.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 142
Through the ECC800Web interface, what can users do? (Multiple choice)
- A. Query version information
- B. Export historical data
- C. Real-time monitoring of device status
- D. Software upgrade
Answer: A,B,C,D
NEW QUESTION 143
......